Place of Origin : Guangdong, China
Output Voltage : 12V AC at 40A
Temperature Sensor : T-type thermocouple (Cu-CuNi)
Brand Name : HongCe
Certification : Calibration Certificate (Cost Additional)
Supply Ability : 10 Sets per Month
Delivery Time : 15-25 working days standard, 30-45 days custom
Net Weight : Approximately 420 kg
Power Supply : AC 380V ±10%, 50Hz, three-phase 5-wire
Test Current : 0-40A AC
Temperature Range : 0°C to +200°C
Payment Terms : T/T,L/C
Temperature Accuracy : ±0.3°C or ±0.5% of reading
Model Number : HC9910C
MOQ : 1 Set
Price : Negotiatable
Number of Stations : 6 stations
Packaging Details : Export-grade plywood case with high-density foam insert, vacuum-sealed moisture barrier, reinforced steel strapping
The Six-Station 0-40A Adjustable Current Temperature Rise Tester by HongCe is a precision thermal evaluation instrument designed for measuring temperature rise in plugs, socket-outlets, connectors, terminals, and electrical contacts under continuous rated current conditions. Fully compliant with international standards including IEC 60884-1, IEC 60669-1, and IEC 60309-1, this system delivers accurate, repeatable thermal performance data essential for product safety certification and quality assessment.
| Parameter | Specification |
|---|---|
| Test Stations | 6 independent stations, expandable |
| Test Current | 0-40A AC, ±0.5% accuracy, THD <1% |
| Output Voltage | 12V AC at 40A (480 VA per station) |
| Temperature Sensors | T-type thermocouples with PT100 ambient reference |
| Temperature Channels | 36 channels total (6 per station), galvanic isolation 500V DC |
| Temperature Range | 0°C to +200°C, ±0.3°C accuracy |
| Display System | 10-inch 1024×600 color TFT HMI touch screen |
| Power Supply | AC 380V ±10%, 50Hz, three-phase, 4 kVA maximum |
| Data Export | USB 2.0 (CSV), RS-232, optional RS-485 Modbus RTU |
| Dimensions | 1400 × 800 × 1700 mm (W×D×H) |
| Weight | Approximately 420 kg |
| Standard | Clause(s) | Requirements |
|---|---|---|
| IEC 60884-1:2013 | Clause 19.1-19.4 | Temperature rise test with limits: terminals ≤45K, accessible metal ≤40K |
| IEC 60669-1:2017 | Clause 18 | Switch temperature rise: terminals ≤45K, ≤30K for switches ≤16A |
| IEC 60309-1:2021 | Clause 22 | Temperature rise for industrial plugs/socket-outlets |
| GB/T 2099.1-2008 | Clause 19 | China national standard equivalent to IEC 60884-1 |
| BS 1363-1:2023 | Clause 17 | UK standard temperature rise test for BS 1363 plugs |
|
|